Domestic polluted Gas Sensor *High selectivity to H2,Alcohol,CO *Small size

Domestic polluted Gas Sensor 

MP135 flat surfaced sensor is used for flammable gas detection, which adopts advanced flat production technology. The heater and metal oxide semiconductor material on the ceramic substrate of subminiature Al2O3 are fetched out by electrode down-lead, encapsulated in metal socket and cap. When the target gas exists, the higher the concentration of target gas in the air, the higher conductivity of sensor is. Use simple electro circuit to convert the variation of conductivity to output signal corresponds to gas concentration.

Features

* High selectivity to H2                                              

* Small size

* 5V rated voltage, low consumption                                   

* Fast response and resume

* Good stability and long life                       

* Simple drive circuit

 

Application

Model

MP135

Type

Semiconductor flat surfaced gas sensor

Standard encapsulation

Metal

Target gas

H2, Alcohol, CO

Detection concentration

10-1000ppm H2

10-1000ppm Alcohol

10-500ppmCO

Standard circuit

Loop voltage

Vc

≤24V  DC

Heating voltage

VH

5.0V±0.2V ACorDC

Load resistance

RL

Adjustable

Standard features of sensor

Heating resistance

RH

110Ω±10Ω(Room Tem.)

Heating consumption

PH

≤240mW

Surface resistance

Rs

10KΩ-100KΩ(in 50ppm H2 )

Sensitivity

S

Rs(in air)/Rs(50ppmH2)≥3

Concentration slope

α

≤0.6(R50ppm/R30ppm H2)

Standard condition of test

Temperature, humidity

20°C±2°C 65%±5%RH

Standard testing circuit

Vc:5.0V±0.1V

     VH: 5.0V±0.1V

Warm-up time

More than 48 hours

Domestic polluted Gas Sensor